Classic 10 |
||||||
![]() |
The MovinCool Classic 10 portable air conditioner is designed to be versatile enough to cool down any type of environment: computer rooms, offices and manufacturing facilities.
|
|
||||
| Electronic Features | Control Panel | Electronic |
| Thermostat Control | Electronic | |
| Cooling Capacity | Rating Conditions: 95F at 60% RH |
10,000 Btu/h |
| Electrical Characteristics |
Voltage Requirement |
1 Phase,115V |
| Total Power Consumption |
1.1 kW | |
| Current Consumption |
10.6 amps | |
| Recommended Fuse Size |
15 amps | |
| NEMA Plug Configuration |
5-15 | |
| Min.Max. Voltage |
105 - 125 | |
| Fans | Motor Output | 0.14 kW |
| Evaporator | Fan Type | Centrifugal |
| Max.Air Flow high/low |
270 CFM | |
| Max. External Static Pressure |
0.33 IWG | |
| Condenser | Fan Type | Centrifugal |
| Max.Air Flow high/low |
740 CFM | |
| Max. External Static Pressure |
0.13 IWG | |
| Compressor | Type | Hermetic Rotary |
| Output | 0.6 kW | |
| Refrigerant | R-22/R-410A | 1.15 lb |
| Dimensions | W x D x H | 19 x 26 x 41 in |
| Net Weight/ Shipping Weight |
145/170 lb | |
| Power Cord | Gauge | 14AWG (3-core) |
| Length | 6 ft | |
| Condensate Tank Capacity |
5 gal | |
| Operating Conditions | Min. Max. (@ 50% RH) | 70° - 105°F |
| Max. Duct Length |
Per Cold Duct Hose |
40 ft |
| Hot Duct Hose | 60 ft | |
| Max. Sound Level |
With Condenser - Duct high/low |
55 dB(A) |
| Without Condenser - Duct high/low |
58 dB(A) | |
| Spot Cooling | Portable design brings 10,000 Btu/hr cooling to the area or room in a highly efficiently way to cool “hot spots.” |
| Weekend/After-hours Cooling | Cost-effective cooling alternative for weekend or after-hours cooling when the building’s air conditioner is shut down |
| Programmable Controller | Backlit control panel with seven-day programming capability allows easy viewing even in low-light conditions |
| Sensitive Electronic Cooling | Set temperatures down to 70°F for offices or 105°F for harsh conditions |
| Easy to Install | No costly installation necessary – roll it in, plug it in, and turn it on |
| Affordable Insurance Policy | Store unit in closet, and install within minutes when the permanent air conditioner is no longer sufficient or completely fails |
| Automatic Restart | Returns the unit to its last operating status in the event of a power failure |
| Freeze Protection | Temperature sensor on evaporator coil prevents ice buildup, which can cause blockage of cool airflow and water leaks |
|
|